3512B Diesel Generator Set

3512B Diesel Generator Set

The 3512B generator set has been developed for a wide range of applications, from emergency standby installations such as healthcare and datacenters to continuously powering remote installations. The packages can be optimized for performance that matters to you with either low emissions or low fuel consumption versions available. Backed by the worldwide network of Cat dealers ready to support your operation with technical support, service, parts, and warranty, Cat generator sets will provide the reliability and durability you expect.

Generator Set Specifications
Standby Rating
1875/1750/1625/1500 kVA
Prime Power Rating
1700/1600/1500/1360 kVA
Emissions/Fuel Strategy
Low Fuel , Low Emissions
Voltage
400 to 415 Volts
Frequency
50 Hz
Speed
1500 rpm
Duty Cycle
Standby, Mission Critical, Prime, Continuous
Minimum Rating
1320 kVA
Maximum Rating
1875 kVA
Engine Specifications
Engine Model
3512B TA, V-12, 4-Stroke Water-Cooled Diesel
Bore
6.69in
Stroke
7.48in
Stroke - HD
8.46in
Displacement
3161.03in³
Displacement - HD
3573.55in³
Compression Ratio
14.0:1 Std 15.5:1 HD
Aspiration
TA
Fuel System
Electronic Unit Injection
Governor Type
ADEMā„¢ A3
Generator Set Dimensions
Length - Minimum
212.8in
Length - Maximum
217.1in
Width - Minimum
90in
Width - Maximum
90in
Height - Minimum
94.9in
Height - Maximum
94.9in
Dry Weight - Genset (minimum)
25620lb
Dry Weight - Genset (maximum)
26530lb

Standard Equipment:

Control System
  • Warnings/shutdown indicators
  • Emergency stop pushbutton
  • 24 Volt DC operation
  • Digital indication for:
  • Lamp test
  • Emergency stop
  • Auto/start/stop control
  • Overspeed
  • Low oil pressure
  • Engine cycle crank
  • Low coolant level
  • Frequency (Hz)
  • 4 Programmable digital inputs
  • Operating hours
  • True RMS AC metering, 3-phase, +/-2% accuracy
  • Communications
  • Oil pressure
  • Speed adjust
  • DC volts
  • High coolant temperature
  • Coolant temperature
  • Amps (per phase & average)
  • Engine cool-down timer
  • RPM
  • EMCP 4.2B
  • Failure to start (overcrank)
  • Volts (L-L & L-N)
  • 4 Programmable digital outputs
  • Alarm acknowledge
 
Governing System
  • ADEM III
 
Cooling System
  • Coolant level sensors
  • SCAC
  • Radiator fan and fan drive
  • Caterpillar extended life coolant
  • Coolant drain line with valve
  • Fan and belt guards
 
Exhaust System
  • Flanged faced outlet(s)
  • Dry exhaust manifold
 
Fuel System
  • Flexible fuel lines
  • Fuel priming pump
  • Secondary fuel filters.
  • Fuel cooler; not included with packages without radiator
 
Generator System
  • Min / max exciter
  • Caterpillar's digital voltage regulator (CDVR)
  • Class H temperature rise at 40C ambient
  • Busbar connections
  • Winding temperature detectors
  • RFI suppression
  • 3 Phase voltage sensing
  • Internal excitation (IE)
  • Random wound
  • 3 phase brushless, Salient pole
  • 6 Leads
  • NEMA Class H insulation
 
Literature
  • English
 
Lube System
  • Gear type lube oil pump
  • Oil filter, filler and dipstick
  • Fumes disposal
  • Oil drain lines and valve
  • Lubricating oil
  • Integral lube Oil cooler
 
Mounting System
  • Rails - Engine/generator/radiator mounting
 
General
  • RH service
  • Flywheel and Flywheel housing-SAE
  • Caterpillar yellow with high gloss black rails & radiator
  • SAE standard rotation
 

Optional Equipment:

Air Inlet System
  • Heavy duty air cleaner
  • Dual element air cleaner
  • Single element filter
 
Exhaust
  • Exhaust mufflers
 
Generator
  • Internal excitation (IE)
  • Oversize and premium generators
  • Permanent magnet excitation (PMG)
  • Anti-condensation heater
 
Control System
  • Generator temperature monitoring
  • Neutral to ground connection
  • Local annunciator modules (Low voltage)
  • EMCP 4.3, EMCP 4.4
  • Cat connect: Ethernet telematics / Satellite telematics / Cell telematics
  • Annunciator modules (Local and remote)
  • Load share module options (LV)
  • CAN2 network equipment
  • Governors (MUI-Low voltage)
  • Customer interface options
  • Annunciator network equipment
  • Remote annunciator module (Low voltage)
  • EMCP voltage and current sensing groups
 
Power Termination
  • Circuit breakers, UL listed
  • Circuit breakers, IEC compliant
 
Cooling System
  • Installed radiators
  • Cooling system attachments
  • Water level switch gauges
  • Coolant
 
Mounting
  • Rubber anti-vibration mounts
  • IBC isolators
  • Spring type vibration isolators
 
Starting/charging
  • Charging alternator
  • Heavy duty starting system
  • Oversize batteries
  • Air starting motor with control and silencer
  • Jacket water heater
  • Battery chargers
 
Exhaust System
  • Y Adapters
  • Mufflers
  • Flexible fittings
  • Flange and exhaust expanders
  • Elbows
 
Factory Support
  • Factory commissioning
 
Fuel System
  • Primary fuel filter
  • Secondary fuel filters
 
Generators And Attachments
  • Low voltage generators 380, 400, 415 Volts 3 Phase, 1500 rpm
  • Space heater kit
  • 1400 and 1600 Frame
  • Pitch 0.6667
  • 6 Leads
  • Internally excitation
  • Generator conversion kits - PM to IE / IE to PM
  • Permanent magnet excitation (PMG)
  • RW
 
General
  • UL 2200 package
  • The following options are based on regional and product configuration:
  • Seismic Certification per applicable building codes: IBC 2000, IBC 2003, IBC 2006, IBC 2009, CBC 2007
  • EU Certificate of Conformance (CE)
 
Instrumentation
  • Pyrometer and thermocouples
 
Lube System
  • Drain GP oil pan
  • Lube oil filters
  • Oil level regulator
  • Standard sump oil pan
  • Lube oil in standard sump
  • Prelube pump groups
 
Crankcase System
  • Crankcase protection group
  • Crankcase ventilation system
 
Mounting System
  • Low efficiency isolators
  • Spring type vibration isolators
  • Low efficiency isolators puck
  • Low isolators
 
Power Connections
  • Low voltage - Package mounted circuit breakers
  • Electrically operated circuit breakers
  • Low voltage - 1400 and 1600 Frame generators
  • Low voltage - Power connection options
 
Special Tests / Reports
  • Standard generator TVA report
  • Standard engine test charge
  • Generator test report
  • PGS Test report @ 1.0 power factor
  • Custom generator TVA report
  • Generator fuel consumption test
  • PGS Test report @ 0.8 power factor
 
Starting / Charging System
  • Batteries, racks and cables
  • 10 Amp Battery charger
  • Starter cover
  • Electric starting motors
  • Jacket water heaters
  • 20 Amp Battery charger
  • Jacket water heater wiring groups
  • 35 Amp Battery charger
 
Extended Service Coverage
  • Silver - 36 ,48, 60, 120 month coverage
  • Gold - 36,48, 60, 120 month coverage
  • Cat branded commercial power system