3516 Diesel Generator Set

3516 Diesel Generator Set

Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.

Generator Set Specifications
Minimum Rating
1600 kVA
Maximum Rating
2000 kVA
Emissions/Fuel Strategy
Low Fuel Consumption
Voltage
380 to 11000 Volts
Frequency
50 Hz
Speed
1500 rpm
Duty Cycle
Standby, Mission Critical, Prime, Continuous
Engine Specifications
Engine Model
3516 TA, V-16, 4-Stroke Water-Cooled Diesel
Bore
6.69in
Stroke
7.48in
Displacement
4210.64in³
Compression Ratio
13.0:1
Aspiration
TA
Fuel System
Mechanical unit injection
Governor Type
Woodward
Generator Set Dimensions
Length - Maximum
232.9in
Width - Maximum
90in
Height - Maximum
93.2in
Dry Weight - Genset (maximum)
33900lb

Standard Equipment:

Air Inlet System
  • Air Cleaner; single element canister type
 
Air Inlet
  • Air Cleaner
 
Cooling
  • Package mounted radiator
 
Exhaust
  • Exhaust flange outlet
 
Fuel
  • Secondary fuel filter
  • Fuel priming pump
  • Primary fuel filter with integral water separator
 
Generator
  • Matched to the performance and output characteristics of Cat engines
  • IP23 Protection
 
Power Termination
  • Bus Bar
 
Control Panel
  • EMCP 4 Genset Controller
 
Control Panels
  • Over / Under voltage (27/59)
  • Serial annunciator module data link
  • Communications:
  • Overcurrent (50/51)
  • Over / Under frequency (81 o/u
  • Text alarm / event descriptions
  • Generator set packages include Caterpillar' s Voltage Regulator.
  • Programmable protective relaying functions:
  • 4 Programmable relay outputs (Form A)
  • Reverse Power (kW) (32)
  • Emergency stop
  • Amps (per phase & average)
  • Oil pressure (psi, kPa or bar)
  • Operating hours
  • 24 Volt DC operation
  • Low oil pressure
  • 6 Customer programmable digital inputs
  • 1 Programmable digital outputs
  • 1 Programmable relay outputs (Form C)
  • Volts (L-L & L-N)
  • Number of I/O varies on options selected:
  • RPM - DC volts
  • Low coolant level
  • kVAr-hr (total)
  • Controls: Speed adjust - Auto / start / stop control - Engine cool-down timer - Engine cycle crank - Alarm acknowledge - Lamp test - Load histogram feature - PLC functionality - Customizable screens -0 True RMS AC metering, 3-phase, +/-2% accuracy
  • kW-hr (total)
  • Failure to start (overcrank)
  • Environmental sealed front face
  • Power Factor (per phase & average)
  • Accessory module data link
  • Generator mounted - rear facing
  • High coolant temperature
  • Overspeed
  • 3 Analog inputs
  • Frequency (Hz)
  • Warning/shutdown with common LED indication of shutdowns for
  • Coolant temperature
  • IVR includes reactive droop capability, 3-phase voltage sensing, KVAR / PF modes, RFI suppression, min /max exciter. Limiter and exciter diode monitor
  • Customer data link (Modbus RTU)
  • kVA (per phase, average & percent)
  • Cat Connect
  • Generator phase sequence
  • Reverse Reactive Power (kVAr) (32RV
  • DC volts
  • kW (per phase, average & percent)
  • kVAr (per phase, average & percent)
  • Emergency stop pushbutton
  • Digital indication for
  • Low coolant temperature
  • EMCP 4.2B
 
Cooling System
  • ATAAC - 3516E Package Radiators shipped installed
  • Certified standard PGS provided
 
Exhaust System
  • Flanged faced outlet(s)
  • Dry exhaust manifold
 
Fuel System
  • Flexible fuel lines - shipped loose
  • Fuel priming pump
  • Fuel cooler; not included with packages without radiator
  • Secondary fuel filters
 
General
  • SAE Standard rotation
  • Flywheel and flywheel housing - SAE No. 00
  • Right hand servicing
  • Caterpillar yellow with high gloss black rails and radiator
 
Generator And Attachments
  • Medium Voltage:
  • Form wound
  • Winding temperature detectors
  • High Voltage:
  • 3 Phase brushless, salient pole
  • Permanent magnet
  • Permanent magnet
  • NEMA standard hole pattern
  • Internal Excitation
  • Six lead
  • Class H insulation, Class F temperature rise at 40C ambient (105C prime/130C standby)
  • Low voltage:
  • Winding temperature detectors
  • NEMA standard hole pattern
  • Form wound
  • Winding temperature detectors
  • Random wound
  • Busbar connections, top center mounted, top cable entry
  • NEMA Class H insulation, Class H temperature rise at 40C ambient (125C prime/150C standby)
  • Anti Condensation Space Heater
  • NEMA Class H insulation, Class H temperature rise at 40C ambient (125C prime/150C standby)
 
Governing System
  • ADEM A3
 
Literature
  • English
 
Lubrication System
  • Gear type lube oil pump
  • Fumes disposal
  • Oil drain lines and valve
  • Lubricating oil
  • Oil filter, filler and dipstick
  • Integral lube oil cool
 
Mounting System
  • Anti-vibration mounts (shipped loose)
  • Rubber anti-vibration mounts (shipped loose)
  • Rails - engine / generator / radiator mounting
 
Starting System
  • Battery disconnect switch
  • Battery and battery rack w/cables
  • 45 Amp charging alternator
  • 24 Volt electric starting motor
 

Optional Equipment:

Air Inlet System
  • Dual element air cleaner
  • Single element filter
 
Exhaust
  • Exhaust mufflers
 
Cooling System
  • Optional installed radiators
  • Coolant
  • Standard ambient ATAAC radiators
  • Optional installed ATAAC radiators
  • Standard ambient radiators
  • Water level switch gauges
 
Generator
  • Internal excitation (IE)
  • Anti-condensation heater
  • Oversize and premium generators
  • Permanent magnet excitation (PMG)
 
Crankcase System
  • No explosion relief valves
  • Ventilation system
  • Explosion relief valves
 
Power Termination
  • Circuit breakers, UL listed
  • Circuit breakers, IEC compliant
 
Control Panels
  • Remote monitoring software
  • Generator temperature monitoring & protection
  • Load share module
  • Digital I/O module
  • EMCP 4.2B
 
Exhaust System
  • Exhaust offset
  • Tier 4 dosing cabinet
  • Flexible fittings
  • Mufflers
  • Tier 4 clean emissions module
  • Elbows
  • Flange and exhaust expanders
  • Tier 4 clean emission MOD Kits
  • Flanges
  • Clean emission parts
  • Y-Adapters
 
Mounting
  • Spring-type vibration isolator
  • IBC isolators
  • Rubber anti-vibration mounts
 
Fuel System
  • Fuel Priming Pumps (Tier 4) - Manual or electric
  • Primary fuel filter
 
Starting/charging
  • Jacket water heater
  • Oversize batteries
  • Battery chargers
  • Air starting motor with control and silencer
  • Heavy-duty starting system
  • Charging alternator
 
General
  • Special paint (Colors other than Caterpillar yellow or high performance paints)
  • US aid emblem
 
Generators And Attachments
  • Thermostate for space heater
  • Alternator air cleaner
  • Differential current transformers (DCT)
  • Differntial current transformers (DCT) 8.7 kV and 15 kV classes
  • Generator conversion
  • Low / medium voltage: 380/400/415 volts, 3 phase 1500 rpm. RW, IE, No. of Leads = 6, Pitch = .6667: 1600 Frame
  • Low / medium voltage: 380/400/415 volts, 3 phase 1500 rpm. RW, PM, No. of Leads = 6, Pitch = .6667: 1600 and 1800 Frames
  • Space heater
 
Instrumentation
  • Pyrometer and thermocouples
 
Lubrication System
  • Oil level regulator
  • Prelube pumps
  • Lube oil in standard sump
 
Mounting System
  • Spring type vibration isolators
  • Puck style low efficiency isolators
  • IBC vibration isolators
 
Power Connections
  • Neutral ground connections
  • Center post busbar
  • Right side power connections
  • Rear power connections
  • 2700 Frame, four lead, four terminal
  • Left side power connections
  • Ground cables between generator and terminal box
  • Low voltage circuit breakers
 
Special Tests / Reports
  • IBC certification
  • Standard engine test charge
  • PGS test report @ 1.0 power factor
  • generator test report
  • Fuel consumption test
  • Canadian Standards Association certification
  • PGS test report @ 0.8 power factor
  • OSHPD certification
  • Torsional vibration analysis reports
  • Generator set fuel consumption test
 
Starting And Charging
  • Electric starting motors
  • Air pressure regulator
  • 24 Volt battery set - Dry
  • Engine barring device
  • Starter cover
  • Air starting motors
  • Jacket water heaters
  • 10, 20, 35 and 50 amp battery chargers
 
Extended Service Coverage
  • Platinum, Gold and Silver coverage
 