3516E Low Voltage Generator Set - Thompson Tractor

3516E Low Voltage Generator Set

3516E Low Voltage Generator Set

Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.

Generator Set Specifications
Standby Rating
3000 ekW
Prime Power Rating
2725 ekW
Emissions/Fuel Strategy
Tier 2
Voltage
416 to 13,800 Volts
Frequency
60 Hz
Speed
1800 rpm
Duty Cycle
Standby, Mission Critical, Prime
Maximum Rating
3000 ekW
Minimum Rating
2725 ekW
Engine Specifications
Engine Model
3516E, V-16, 4-Stroke, Water-Cooled Diesel
Bore
6.69in
Stroke
8.47in
Displacement
4765in³
Compression Ratio
13.9:1 / 14.3:1
Aspiration
ATAAC
Fuel System
MEUI
Governor Type
Ademā„¢ A5
Generator Set Dimensions
Length - Maximum
304in
Width - Maximum
113in
Height - Maximum
143in
Dry Weight - Genset (maximum)
44930lb

Standard Equipment:

Air Inlet System
  • Single element canister type with service indicator
  • Air cleaner
 
Cooling
  • Package mounted radiator
 
Exhaust
  • Exhaust flange outlet
 
Fuel
  • Primary fuel filter with integral water separator
  • Fuel priming pump
 
Generator
  • IP23 Protection
  • Matched to the performance and output characteristics of Cat engines
 
Power Termination
  • Busbar
 
Starting/charging
  • Heavy duty starting system
  • Charging alternator
 
Control Panel
  • Over/under voltage (27/59)
  • Emergency stop pushbutton
  • Speed adjust
  • Accessory module data link
  • Generator phase sequence
  • Panel lights
  • Alarm acknowledge
  • Generator mounted - rear facing
  • kW (per phase, average & percent)
  • Engine cool-down timer
  • Communications:
  • High coolant temperature
  • Warning/shutdown with common LED indication of shutdowns for:
  • Overcurrent (50/51)
  • Amps (per phase & average)
  • Oil pressure (psi, kPa or bar)
  • Serial annunciator module data link
  • 24 Volt DC operation
  • Cat ECS controller includes:
  • DC volts
  • Reverse reactive power (kVAr) (32RV)
  • 6 Programmable digital inputs
  • 2 Programmable relay outputs (Form C)
  • Frequency (Hz)
  • Customer data link (Modbus RTU)
  • Power factor (per phase & average)
  • kW-hr (total)
  • Cat ECS 100
  • Lamp test
  • kVA (per phase, average & percent)
  • kVAr-hr (total)
  • Coolant temperature
  • Text alarm/event descriptions
  • Over/under frequency (81 o/u)
  • kVAr (per phase, average & percent)
  • 4 Programmable relay outputs (Form A)
  • Low coolant level
  • True RMS AC metering, 3-phase, +/-2% accuracy
  • Failure to start (overcrank)
  • Operating hours
  • Low coolant temperature
  • 2 Programmable digital outputs
  • Low oil pressure
  • Controls:
  • Digital indication for:
  • Environmental sealed front face
  • Overspeed
  • Volts (L-L & L-N)
  • Reverse power (kW) (32)
  • Engine cycle crank
  • Programmable protective relaying functions:
 
Cooling System
  • Fan and belt guards
  • JWAC
  • Radiator fan and fan drive
  • Coolant level sensors
  • Caterpillar extended life coolant
  • Coolant drain line with valve
 
Exhaust System
  • Flanged faced outlet(s)
  • Dry exhaust manifold
 
Fuel System
  • Fuel cooler; not included with packages without radiator
  • Fuel priming pump
  • Secondary fuel filters
  • Flexible fuel lines - shipped loose
 
Generators And Attachments
  • Class H insulation, Class F temperature rise at 40C ambient (105C prime/130C standby)
  • NEMA standard hole pattern
  • Anti-condensation space heater
  • Permanent magnet excitation (PMG)
  • Form wound
  • 3 Phase brushless, Salient pole
  • 6 Lead
  • Winding temperature detectors
  • Right side extension terminal box, busbar connections, top mounted, bottom cable entry
 
Governing System
  • ADEM III
 
Literature
  • Parts book
 
Lube System
  • Gear type lube oil pump
  • Integral lube Oil cooler
  • Fumes disposal
  • Oil drain lines and valve
  • Oil filter, filler and dipstick
  • Lubricating oil
 
Mounting System
  • Rubber anti-vibration mounts - shipped loose
  • Rails - engine/generator/radiator mounting
 
Starting / Charging System
  • 45 Amp Charging alternator
  • Battery and battery rack w/cables
  • Battery disconnect switch
  • 24 Volt electric starting motor
 
General
  • Right hand servicing
  • Paint - Caterpillar yellow with high gloss black rails & radiator
  • SAE standard rotation
  • Flywheel and flywheel housing-SAE No. 00
 

Optional Equipment:

Air Inlet System
  • Air inlet protection
  • Remote air inlet adapters
  • Heavy duty air cleaners
  • Dual element air cleaners
 
Circuit Breakers
  • 2000, 2500, 3200, 4000 Amp, 4 Pole, IEC rated Circuit breakers
  • Circuit breaker harnesses
  • Masterpact breaker connections
  • P Frame breaker connections
  • 2000, 2500, 3200, 4000, 5000 Amp, 3 Pole, IEC rated Circuit breakers
  • Busbar connections
  • R Frame breaker connections
  • Cable entry options
  • 1600, 2000, 2500, 3000, 4000, 5000 Amp, 3 Pole, UL-100% rated Circuit breakers
  • Optional busbar power connections
 
Power Termination
  • Circuit breakers, IEC compliant
 
Control Panel
  • Voltage raise/lower switch
  • PC monitoring (Remote and local)
  • Generator temperature monitoring
  • Remote speed adjust
  • Annunciator modules
  • EMCP 4.4
  • Vandal proof panel door
  • Auxiliary box
  • Customer interface options
  • Ground
  • Language options
  • Load share module options
  • Mounting group - External box clips
 
Cooling System
  • Optional Serpentine radiators
  • Optional ATAAC radiators
  • Water level switch gauges
  • Expansion tanks
 
Exhaust System
  • Flexible fittings
  • Y Adapters
  • Elbows
  • Mufflers
  • Flanges
  • Flanges and exhaust fittings
 
Fuel System
  • Duplex fuel filters
  • Primary fuel filters
 
Generators And Attachments
  • Differential current transformers - 8.7 and 15 kV class
  • Alternator air cleaners
 
Instrumentation
  • Pyrometer and thermocouples
 
Lube System
  • Manual prelube pump
  • Electric prelube pumps
  • Oil level regulator
  • Lube oil in standard sump
 
Mounting System
  • Spring type vibration isolators
  • IBC Seismic vibration isolators NORAD
  • Puck style low efficiency lsolators
 
Power Connections
  • Neutral ground connections
  • 2700 & 3000 Frame
  • Grounding groups
 
Special Tests / Reports
  • Fuel consumption test
  • Torsional vibration analysis
  • Standard engine test charge
  • IBC Certifications
  • Generator set consumption test
  • Generator set test report
  • PGS Test report @ 1.0 power factor
  • PGS Test report @ 0.8 power factor
 
Starting / Charging System
  • Engine barring group
  • 10, 20, 35 and 50 Amp Battery chargers
  • Starter cover
  • Jacket water heaters
  • 24 Volt battery set - Dry
  • Electric starting motors
  • Air starting motors
  • Air pressure regulator
 
General
  • US aid emblem
  • Special paint colors
 

    This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.