Generator Set Specifications
Minimum Rating
2750 kVA
Maximum Rating
3000 kVA (3100 kVA without fan)
Emissions/Fuel Strategy
Low Fuel Consumption
Voltage
380 to 11000 volts
Frequency
50 Hz
Speed
1500 rpm
Duty Cycle
Standby, Mission Critical, Prime
Engine Specifications
Engine Model
3516E, SCAC, V-16, 4-Stroke, Water-Cooled Diesel
Bore
6.69in
Stroke
8.46in
Displacement
4766in
Compression Ratio
14:01
Aspiration
TA
Fuel System
Electronic unit injection
Governor Type
Adem™5
Generator Set Dimensions
Length - Maximum
296.8in
Width - Maximum
87.2in
Height - Maximum
133.5in
Dry Weight - Genset (maximum)
43541lb

Standard Equipment:

Air Inlet System
  • Air cleaner
  • Single element canister type with service indicator
 
Control Panel
  • Environmental sealed front face
  • Warning/shutdown with common LED indication of shutdowns for:
  • Overspeed
  • RPM
  • Generator phase sequence
  • Emergency stop pushbutton
  • Digital indication for:
  • Text alarm / event descriptions
  • 2 Programmable digital outputs
  • Reverse reactive power (kVAr) (32RV)
  • Reverse power (kW) (32)
  • Failure to start (overcrank)
  • Panel lights
  • Speed adjust
  • Oil pressure (psi, kPa or bar)
  • Low coolant level
  • Generator mounted - rear facing
  • Over / under frequency (81 o/u)
  • Lamp test
  • True RMS AC metering, 3-phase, +/-2% accuracy
  • Low coolant temperature
  • Power Factor (per phase & average)
  • Frequency (Hz)
  • Overcurrent (50/51)
  • High coolant temperature
  • DC volts
  • 6 Programmable digital inputs
  • Coolant temperature
  • 24 Volt DC operation
  • Amps (per phase & average)
  • Emergency stop
  • Alarm acknowledge
  • Programmable protective relaying functions:
  • 2 Programmable relay outputs (Form C)
  • EMCP 4.2B
  • Serial annunciator module data link
  • Controls:
  • kW-hr (total)
  • kW (per phase, average & percent)
  • Engine cool-down timer
  • Operating hours
  • EMCP 4 Genset Controller
  • Volts (L-L & L-N)
  • Engine cycle crank
  • Communications:
  • kVAr (per phase, average & percent)
  • EMCP4.2B controller includes:
  • Customer data link (Modbus RTU)
  • Over / under voltage (27/59)
  • Low oil pressure
  • kVA (per phase, average & percent)
  • kVAr-hr (total)
  • 4 Programmable relay outputs (Form A)
  • Accessory module data link
 
Exhaust
  • Exhaust flange outlet
 
Fuel
  • Primary fuel filter with integral water separator
 
Generator
  • IP23 Protection
  • Matched to the performance and output characteristics of Cat engines
 
Power Termination
  • Busbar
 
Starting/charging
  • Heavy-duty starting system
  • Charging alternator
 
Cooling System
  • Caterpillar Extended Life Coolant
  • Radiator fan and fan drive
  • Fan and belt guards
  • JWAC
  • Coolant drain line with valve
  • Coolant level sensors
 
Cooling
  • Package mounted radiator
 
Exhaust System
  • Dry exhaust manifold
  • Flanged faced outlet(s)
 
Fuel System
  • Secondary fuel filters
  • Fuel priming pump
  • Fuel cooler; not included with packages without radiator
  • Flexible fuel lines - shipped loose
 
Generators And Attachments
  • Internal excitation
  • 6 Lead
  • Busbar connections, top center mounted, top cable entry
  • IEC standard hole pattern
  • Random wound
  • 3 Phase brushless, salient pole
  • Winding temperature detectors
  • NEMA Class H insulation, Class H temperature rise at 40C ambient (125C prime / 150C standby).
  • Generator set packages include Caterpillar's Digital Voltage Regulator (CDVR). CDVR includes reactive droop capability, 3-phase voltage sensing, KVAR/PF modes, RFI suppression, min/max exciter
 
Governing System
  • ADEM III
 
Literature
  • English
 
Lube System
  • Lubricating oil
  • Oil filter, filler and dipstick
  • Fumes disposal
  • Oil drain lines and valve
  • Gear type lube oil pump
  • Integral lube oil cooler
 
Mounting System
  • Rubber anti-vibration mounts (shipped loose)
  • Rails - engine / generator / radiator mounting
 
Starting / Charging System
  • Battery and battery rack w/cables
  • 24 Volt electric starting motor
  • Battery disconnect switch
 
General
  • Right hand servicing
  • Paint: Caterpillar yellow with high gloss black rails & radiator
  • Flywheel and flywheel housing-SAE No. 00
  • SAE standard rotation
 

Optional Equipment:

Air Inlet System
  • Air inlet protection
  • Heavy duty air cleaners
  • Remote air inlet adapters
  • Dual element air cleaners
 
Circuit Breakers
  • Cable entry options
  • Control packaging for enclosures
  • Optional busbar power connections
  • EMAX breakers
  • Load take off; IEC standard hole
  • Center posts busbars
  • Trip Units
 
Power Termination
  • Circuit breakers, IEC compliant
 
Control Panels
  • External box clips
  • Local and remote monitoring
  • Busbar connections
  • Governors
  • Generator temperature monitoring
  • Auxiliary box
  • Voltage raise / lower switch
  • EMCP 4.3, EMCP 4.4
  • EMAX breaker connections
  • Language options
  • Remote speed adjust
  • Annunciator modules
  • Customer interface options
  • Vandal proof panel door
 
Cooling System
  • Optional Serpentine radiators
  • Water level switch gauges
  • Heat exchangers
  • Radiator duct flanges
 
European Certifications
  • EU declaration of conformity
 
Exhaust System
  • Mufflers
  • Through wall installation kit
  • Flexible fittings
  • Muffler mounting kits
 
Fuel System
  • Fuel coolers
  • Primary fuel filter
 
Generators And Attachments
  • 3 Phase, Random wound, Internal excitation
  • Internal excitation
  • Random wound
  • Pitch: 0.6667
  • Optional generators
  • Number of leads: 6
  • 3 Phase, 380 / 400 / 415 / 3300 / 6600 / 10000 / 10500 / 11000 volt
     
 
Instrumentation
  • Thermocouples
  • Pyrometers and thermocouples
 
Lube System
  • Manual prelube sump pumps
  • Oil level regulator
  • Electric prelube pumps
 
Mounting System
  • Spring type vibration isolators
  • IBC vibration isolators
 
Protection System
  • Explosion relief valves
 
Special Tests / Reports
  • PGS test report @ 0.8 power factor
  • CSA test and certification
  • Neutral ground certificate
  • PGS test report @ 1.0 power factor
  • IBC seismic certificate
 
Starting / Charging System
  • Jacket water heaters
  • ETHER starting aids
  • Dual 24 volt electric starting motors
  • 24 Volt battery sets - Dry
  • Charging alternators - 50 Amp
  • 10 and 20 amp battery chargers
 
General
  • Engine barring group
 

    This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.