C18 Generator Set

C18 Generator Set

Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.

Generator Set Specifications
Maximum Rating
850 kVA
Minimum Rating
706 kVA
Emissions/Fuel Strategy
Low Fuel
Voltage
380 to 415 Volts
Frequency
50 Hz
Speed
1500
Duty Cycle
Standby, Prime
Engine Specifications
Engine Model
C18 ATAAC, I-6, 4-Stroke Water-Cooled Diesel
Bore
5.71in
Stroke
7.2in
Displacement
1106.4in³
Compression Ratio
14.5:1
Aspiration
Air to Air Aftercooled
Fuel System
Electronic unit injection
Governor Type
Ademā„¢A4
Generator Set Dimensions
Length - Maximum
162.4in
Width - Maximum
78.3in
Height - Maximum
75in

Standard Equipment:

Air Inlet System
  • Single element air cleaner
  • Turbocharger
  • Aftercooler core
  • Light duty air cleaner
 
Control System
  • GCCP 1.3
 
Cooling
  • Coolant drain line with valve
  • Radiator and cooling fan with guard
  • Fan drive, battery charging alternator drive
  • Caterpillar extended life coolant
 
Exhaust System
  • Stainless steel exhaust flex gaskets, raincap and SAE exhaust flange for customer use - shipped loose
 
Fuel System
  • Standard 8 hour open set integral fuel tank
 
Generator And Attachments
  • LC frame generator - IP23 Protection
  • Matched to the performance and output characteristics of Cat engines
  • Segregated low voltage (AC/DC) wiring panel
  • Mandatory option circuit breaker, IEC, 3 pole, mounted in power centre
  • Integrated voltage regulator (IVR)
  • Power center, IP22
  • Integrated voltage regulator (IVR)
 
Governing System
  • Cat electronic governor (ADEM A4)
 
Lube System
  • Lubricating oil
  • Oil drain lines with valves
 
Mounting System
  • Captive linear vibration isolators between base and engine-generator.
 
Starting/charging
  • 24 Volt battery with rack and cables
 
General
  • Engine and alternator pre-paint, Caterpillar yellow
 

Optional Equipment:

Air Inlet System
  • Dual element air cleaner
 
Circuit Breakers
  • 4 Pole (IEC-100% rated) Circuit breakers - Package mounted
  • Circuit breaker (IEC) Auxiliary contacts
  • 3 Pole (IEC-100% rated) Circuit breakers - Motorised
  • Padlockable circuit breaker device
  • Shunt trip for IEC breaker
  • Power terminal strip
  • 4 Pole (IEC-100% rated) Circuit breakers - Motorised
  • 3 Pole (IEC-100% rated) Circuit breakers - Package mounted
 
Control System
  • Local alarm horn
  • Protective devices: Earth fault relay - earth leageage Ground fault relay - Overload shutdown via breaker - Low fuel level alarm - Low fuel level shutdown - High fuel level alarm - Fuel level sensor
  • GCCP 1.4
  • Remote annunciator module
  • Oil temperature displays
  • Local alarm modules
 
Cooling System
  • Radiator transition flange
  • Low coolant temperature alarm
 
Enclosures
  • Sound attenuated enclosures (to be available soon)
 
Exhaust System
  • 8 and 10 inch elbow kits
  • 10, 25, 35 dB end in / end out mufflers
  • Engine mounted muffler
  • 8 and 10 inch GP flanges
  • Manifold and turbocharger guards
 
Fuel System
  • Integral - Dual wall fuel tank base
  • Fuel transfer system
  • Manual fuel transfer pump
 
Generator And Attachments
  • Space heaters
  • A Frame CIP generator
  • LC frame CIP generator
  • A Frame oversize generator
  • Ingress protection
  • LC frame oversize generators
  • LC frame generator
  • Permanent magnet excitation (PMG)
 
Lube System
  • Manual sump pump
 
Starting And Charging
  • Jacket water heaters
  • 5 Amp Battery charger
  • Battery disconnect switch
  • Jacket water heaters
 