C2.2 Generator Set

C2.2 Generator Set

Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.

Generator Set Specifications
Maximum Rating
22.0 kVA
Minimum Rating
13.0 kVA
Emissions/Fuel Strategy
R96/EUIIIa Equivalent
Voltage
110 to 415 Volts
Frequency
50 Hz
Speed
1500 rpm
Duty Cycle
Standby, Prime
Engine Specifications
Engine Model
CatĀ® C2.2, In-line 4, 4-cycle diesel
Bore
3.3in
Stroke
3.9in
Displacement
135.2in³
Compression Ratio
22.5:1
Aspiration
Naturally Aspirated
Fuel System
Indirect Injection
Governor Type
Mechanical
Generator Set Dimensions
Length - Maximum
59.1in
Width - Maximum
24.4in
Height - Maximum
43.9in

Standard Equipment:

Control Panel
  • GCCP 1.3
 
Air Inlet System
  • Air cleaner; light duty with disposable element
 
Cooling System
  • Radiator and cooling fan with guards
  • Caterpillar extended life coolant
  • Coolant drain line with valve
  • Fan drive, battery charging alternator drive
 
Fuel System
  • Standard open set fuel tank/base supplied
  • Base, formed steel with single wall integral 8-hour fuel tank
 
Exhaust System
  • Stub pipe, gaskets, raincap & SAE exhaust flange for customer use - shipped loose
 
Generators And Generator Attachments
  • Voltage regulator (single phase sensing)
  • Segregated low voltage (AC/DC) wiring panel
  • Tower panel, IP22, bottom cable entry
  • IP23 Protection
  • Circuit breaker, IEC, 3 pole, mounted in tower panel
  • 12 Leads
 
Governing System
  • Mechanical governing system
 
Lube System
  • Oil drain line with valve
  • Lubricating oil
 
Mounting System
  • Captive linear vibration isolators between base and engine-generator
  • includes lifting provisions and termination points for coolant
 
Starting / Charging System
  • 12 Volt battery with rack and cables
 
General
  • Engine and alternator pre-paint, Caterpillar yellow
 

Optional Equipment:

Alternator Options
  • Coastal insulation protection
 
Certificates
  • European upgrade to STD set for CE certificate
  • Global certification for CIS
 
Circuit Breakers
  • Padlockable breaker device
  • 4 Pole Circuit breaker
 
Control Panel Options
  • Emergency stop with key
  • Volt free contacts for common alarm
  • Volt free contacts for genset running
  • GCCP 1.3
  • Battery charger
 
Cooling System
  • Coolant heater
 
Enclosures
  • Sound attenuated enclosure (GALV)
  • Single point lift for enclosure
 
Fuel System
  • Low fuel level alarm
 
Mounting Options
  • Industrial silencer removal
  • Silencer installation kit
  • Battery removal
 
Special Test And Inspection
  • PGS Test report @ 1.0 power factor
 
General
  • Packing case - compact set
  • Packing case - canopied set
  • Radiator stone guard
 

    This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.