C9 Generator Set

Product Description

Producing reliable power from 180 to 300 ekW at 60 Hz, our C9 diesel generator sets designed to ISO 8528-5 transient response requirements. All C9 generator sets are engineered to EPA Stationary Emergency (Tier 3) emissions standards with low fuel consumption.

Generator Set Specifications

Maximum Rating
300 ekW
Minimum Rating
180 ekW
Emissions/Fuel Strategy
EU Stage IIIA, Low Fuel
Voltage
220 to 480 Volts
Frequency
60 Hz
Speed
1800 rpm
Duty Cycle
Standby, Prime

Engine Specifications

Engine Model
C9 ATAAC, I-6, 4-Stroke Water-Cooled Diesel
Bore
4.41in
Stroke
5.87in
Displacement
537.01in³
Compression Ratio
16.1:1
Aspiration
Air to Air Aftercooled
Fuel System
Hydraulic electronic unit injection
Governor Type
Adem™A4

Generator Set Dimensions

Length - Maximum
157in
Width - Maximum
47.5in
Height - Maximum
73.5in

Standard Equipment

  • Air Inlet System
    • Air cleaner, light duty with disposable paper filter
    • Turbocharger
    • Air cleaner, light duty with disposable paper filter
  • Control Panels
    • GCCP 1.3
    • EMCP4.4 control panel
  • Cooling System
    • Radiator and cooling fan with guard
    • Fan drive, battery charging alternator drive
    • Coolant drain line with valve
    • Caterpillar extended life coolant
    • Radiator and cooling fan with guard
  • Exhaust System
    • Stainless steel exhaust flex, gaskets, rain cap & SAE exhaust flange for customer use - shipped loose
    • Flange for customer; shipped loose
    • Stainless steel exhaust flex, gaskets, rain cap and SAE exhaust
  • Fuel System
    • Standard open set fuel tank/base supplied
    • Base, formed steel with single wall integral 8-hour fuel tank
    • Standard open set fuel tank/base supplied
    • Base, formed steel with single wall integral 8-hour fuel tank
  • Generators And Generator Attachments
    • Mandatory option circuit breaker, IEC, 3 pole mounted in power centre
    • Power centre, IP22
    • Voltage regulator (single phase sensing)
    • 12 Leads
    • IP23 Protection
    • Segregated low voltage (AC/DC) wiring panel
    • IP23 Protection
    • 12 Leads
  • Governing System
    • Cat electronic governor (ADEM A4)
    • Cat electronic governor (ADEM A4)
  • Lube System
    • Oil cooler
    • Lubricating oil
    • Oil drain valves
  • Mounting System
    • Captive linear vibration isolators between base and engine-generator
    • Includes lifting provisions and termination points for coolant and lube oil drain lines
  • Starting / Charging System
    • 24V battery with rack and cables
  • General
    • Engine and alternator re-paint, Caterpillar yellow
    • Engine and alternator re-paint, Caterpillar yellow

Optional Equipment

  • Certifications
    • European Certificate for Conformance
    • Global Certification for CIS
  • Air Inlet System
    • Single element air cleaner
  • Circuit Breakers
    • 4 Pole (IEC-100% rated) Circuit breaker upgrades: 400, 630, 800 and 100 amps
  • Control Panels
    • Oil temperature displays
    • Control panel protective devices: Earth fault relay ; Earth leakage ground fault ; overload shutdown via breaker ; Low fuel level shutdown ; Low fuel level alarm ; Fuel level sensor
  • Cooling System
    • Radiator duct flange
    • Low coolant temperature alarm
  • Enclosures
    • Sound attenuated enclosure
    • High ambient sound attenuated enclosure
  • Exhaust System
    • Mufflers - End in/end out; 10 dBA or 25 dBA attenuation
    • 5 and 6 inch elbow kits
    • 6 inch flange
    • 5 - 6 inch flange adaptor
  • Fuel System
    • Integral dual wall fuel tank base
  • Generators And Attachments
    • Permanent magnet excitation (PMG) generator
    • Oversize, AREP, CIP generators
  • Mounting System
    • Narrow skid base
  • Starting / Charging System
    • Battery disconnet switch
    • Jacket water heater
    • 5 Amp single Battery charger