Generator Set Specifications
Maximum Rating
45 ekW
Duty Cycle
Standby
Emissions/Fuel Strategy
Non Regulated
Voltage
220 to 480 Volts
Frequency
60 Hz
Speed
1800 rpm
Minimum Rating
45 ekW
Engine Specifications
Engine Model
Cat® C3.3, In-line 3, 4-cycle diesel
Bore
4.1in
Stroke
5in
Displacement
201.4in³
Compression Ratio
17.25:1
Aspiration
Turbocharged
Fuel System
Inline
Governor Type
Mechanical
Generator Set Dimensions
Length - Maximum
89.7in
Width - Maximum
35.4in
Height - Maximum
52in
Dry Weight - Genset (maximum)
1031lb

Standard Equipment:

Engine
  • C3.3, Inline 3 cylinder, 4 stroke diesel
 
Genset Control
  • GCCP 1.1
 
Governor
  • Mechanical governor
 
Alternator
  • A Frame standard alternator
 
Fuel Storage
  • Single wall 8 hour fuel tank
 
Enclosure
  • Cat GC enclosure
 
Air, Cooling & Exhaust
  • Enclosure silencer
 
General
  • Engine and alternator pre-paint, Caterpillar yellow
 

Optional Equipment:

Certification
  • Certificate of Conformance
  • Australia, CIS, Gulf Certification
 
Auxiliary Supply Voltage
  • 120V
 
Alternator Requirements
  • Space heater
 
Fuel Storage
  • Dual wall 8 hour fuel tank
  • Single wall tank with containment
  • Low fuel level shutdown
  • Low fuel level alarm
  • High fuel level alarm
 
Genset Control
  • Battery charger
  • Volt free contacts for common alarm
  • Volt free contacts for genset running
  • Earth leakage
  • Earth fault
  • USB to RS485 Communications device
  • Emergency stop with key
  • Panel mounted audible alarm
  • Coolant heater
  • Standby Pack (Smart Jacket water heater, Battery charger)
  • Battery
  • Low coolant level shutdown
 
Circuit Breaker
  • 3 Pole Circuit breaker 63A
  • 3 Pole Circuit breaker 80A
  • 3 Pole Circuit breaker 100A
  • 3 Pole Circuit breaker 125A
  • 3 Pole Circuit breaker 160A
  • 3 Pole Circuit breaker 200A
  • 4 Pole Circuit breaker 63A
  • 4 Pole Circuit breaker 80A
  • 4 Pole Circuit breaker 100A
  • 4 Pole Circuit breaker 125A
  • 4 Pole Circuit breaker 160A
  • 4 Pole Circuit breaker 200A
  • Circuit breaker padlock
  • Neutral earth link
  • Overload via alarm switch on breaker
 
Testing & Packaging
  • PGS Test report @ 1.0 power factor
  • PGS Test report @ 0.8PF
 