Generator Set Specifications
Maximum Rating
500 ekW
Minimum Rating
500 ekW
Emissions/Fuel Strategy
Non Regulated
Voltage
220 to 480 Volts
Frequency
60 Hz
Speed
1800 RPM
Duty Cycle
Standby
Engine Specifications
Engine Model
C13 In-line 6, 4-cycle diesel
Bore
5.1in
Stroke
6.2in
Displacement
763in³
Compression Ratio
15.8:1
Aspiration
Turbocharged Air-to-Air Aftercooled
Fuel System
EUI
Governor Type
Ademā„¢A4
Generator Set Dimensions
Length - Maximum
122in
Width - Maximum
52.7in
Height - Maximum
85.4in
Dry Weight - Genset (maximum)
6693lb

Standard Equipment:

Engine
  • Cat® C13 Inline 6 cylinder, 4 stroke diesel
 
Control Panels
  • GCCP 1.1
 
Governor
  • Mechanical governor
 
Alternator
  • A Frame standard alternator
 
Fuel Storage
  • Single wall 8 hour fuel tank
 
Cooling System
  • Radiator and cooling fan with guards
  • Fan drive, battery charging alternator drive
 
Electrical Options
  • 3 Pole Circuit breaker
  • Neutral earth link
  • 24 Volt battery with rack and cables
 
Air Inlet System
  • Air cleaner; light duty with disposable element
 
Lube System
  • Lubricating oil
  • Oil drain line with valve
 
Mounting System
  • Captive linear vibration isolators
  • Lifting provision and drag points
 
General
  • Engine and alternator pre paint, Caterpillar yellow
  • Engine and alternator pre-paint, Caterpillar yellow
 
Generator And Attachments
  • Mandatory option circuit breaker, IEC, 3 pole, mounted in power centre
 
Packaged Generator Set
  • Service indicator
  • Radiator package mounted
  • Disposable air filter
  • Coolant level sight gauge
  • Coolant drain line with valve
  • Low coolant level sensor
 
Governing System
  • Cat electronic governor (ADEM A4)
 
Lube System
  • Lubricating oil
  • Oil cooler
  • Oil drain valves
 
Mounting System
  • Captive linear vibration isolators between base and engine-generator
  • Includes lifting provisions and termination points for coolant and lube oil drain lines
 
Starting / Charging System
  • 24V battery with rack and cables
 

Optional Equipment:

Control Panel
  • Speed and Voltage adjust potentiometers
  • PLG 4G/3G/Ethernet
  • Annunciator
  • Emergency E-Stop
 
Enclosure
  • Cat GC enclosure
 
Electrical Options
  • 4 Pole Circuit breaker
  • Auxiliary contacts
  • Padlockable circuit breaker
  • Battery charger
  • Wet battery
 
Circuit Breakers
  • Shunt trip for IEC circuit breaker
  • 4 Pole (IEC-100% rated) Circuit breaker - Motorised
  • Circuit breaker (IEC) Auxiliary contacts
 
Alternator
  • Space heater
  • AVR
 
Exhaust System
  • Industrial silencer
  • 10 dBA Attenuation silencer
  • 6 and 8 inch flange GP
  • Flexible 8 inch exhaust fittings
  • 6 and 8 inch elbow kit
  • 10, 25 and 35 dBA attenuation
 
Air Inlet System
  • Single stage air filter
  • Dual element air filter
 
Certifications
  • EU Certificate of Conformance (CE)
  • EAC Certification
 
Extended Service Coverage
  • 3, 4, 5 and 10 Years
 
Fuel System
  • Dual wall 8 hour fuel tank
  • Single wall 8 hour fuel tank with spill containment
  • Low fuel level shutdown
  • Low and high fuel level alarms
  • Fuel transfer system controls
  • Manual fuel transfer pump
  • Integral dual wall fuel tank base
 
Generator And Attachments
  • LC frame generator
  • Ingress protection
  • LC CIP generator
  • A Frame CIP generator
  • Permanent magnet excitation (PMG) generator
  • A Frame oversize generator
  • Space heaters
 
Lube System
  • Manual sump pump
 
Mounting System
  • Narrow skid base
 
Starting / Charging System
  • Jacket water heater
  • Battery disconnect switch
  • 5 Amp single Battery charger
 