DE55 GC Generator Set (60 Hz)

DE55 GC Generator Set (60 Hz)

DE55 GC Generator Set (60 Hz)

Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.

Generator Set Specifications
Frequency
60 Hz
Maximum Rating
50 ekW
Emissions/Fuel Strategy
Non Regulated
Voltage
220 to 480 Volts
Minimum Rating
50 ekW
Speed
1800 rpm
Duty Cycle
Standby
Engine Specifications
Engine Model
Cat® C3.3, In-line 3, 4-cycle diesel
Bore
4.1in
Stroke
5in
Displacement
201.4in³
Compression Ratio
17.25:1
Aspiration
Turbocharged
Fuel System
Inline
Governor Type
Mechanical
Generator Set Dimensions
Length - Maximum
76.6in
Width - Maximum
34.3in
Height - Maximum
48.7in
Dry Weight - Genset (maximum)
2114lb

Standard Equipment:

Engine
  • C3.3, Inline 3 cylinder, 4 stroke diesel
 
Genset Control
  • GCCP 1.1
 
Governor
  • Mechanical governor
 
Alternator
  • A Frame standard alternator
 
Fuel Storage
  • Single wall 8 hour fuel tank
 
Enclosure
  • Cat GC enclosure
 
Air, Cooling & Exhaust
  • Enclosure silencer
 
General
  • Engine and alternator pre-paint, Caterpillar yellow
 

Optional Equipment:

Certification
  • Australia, CIS, Gulf Certification
  • Certificate of Conformance
 
Alternator Requirements
  • Space heater
 
Auxiliary Supply Voltage
  • 120V
 
Fuel Storage
  • Dual wall 8 hour fuel tank
  • Low fuel level shutdown
  • Single wall tank with containment
  • Low fuel level alarm
  • High fuel level alarm
 
Genset Control
  • Battery charger
  • Volt free contacts for genset running
  • Volt free contacts for common alarm
  • Emergency stop with key
  • Earth leakage
  • USB to RS485 Communications device
  • Earth fault
  • Panel mounted audible alarm
  • Battery
  • Standby Pack (Smart Jacket water heater, Battery charger)
  • Coolant heater
  • Low coolant level shutdown
 
Circuit Breaker
  • 3 Pole Circuit breaker 63A
  • 3 Pole Circuit breaker 80A
  • 3 Pole Circuit breaker 100A
  • 3 Pole Circuit breaker 125A
  • 3 Pole Circuit breaker 160A
  • 3 Pole Circuit breaker 200A
  • 4 Pole Circuit breaker 63A
  • 4 Pole Circuit breaker 80A
  • 4 Pole Circuit breaker 100A
  • 4 Pole Circuit breaker 125A
  • 4 Pole Circuit breaker 160A
  • 4 Pole Circuit breaker 200A
  • Circuit breaker padlock
  • Neutral earth link
  • Overload via alarm switch on breaker
 
Testing & Packaging
  • PGS Test report @ 1.0 power factor
  • PGS Test report @ 0.8PF
 