DE88 GC Generator Set (50 Hz)

DE88 GC Generator Set (50 Hz)

DE88 GC Generator Set (50 Hz)

Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.

Generator Set Specifications
Maximum Rating
88 kVA
Minimum Rating
88 kVA
Emissions/Fuel Strategy
Non Regulated
Voltage
380 to 415 Volts
Frequency
50 Hz
Speed
1500 rpm
Duty Cycle
Standby
Engine Specifications
Engine Model
C4.4, In-line 4, 4-cycle diesel
Bore
4.1in
Stroke
5in
Displacement
268.5in
Compression Ratio
17.25:1
Aspiration
Turbocharged
Fuel System
Inline
Governor Type
Mechanical
Generator Set Dimensions
Length - Maximum
89.6in
Width - Maximum
43.3in
Height - Maximum
57.7in
Dry Weight - Genset (maximum)
1245lb

Standard Equipment:

Engine
  • C4.4, Inline 4 cylinder, 4 stroke diesel
 
Fuel Storage
  • Single wall 8 hour fuel tank
 
Governor
  • Mechanical governor
 
Alternator
  • A Frame standard alternator
 
Genset Control
  • GCCP 1.1
 
Enclosure
  • Cat GC enclosure
 
Air, Cooling & Exhaust
  • Enclosure silencer
 
General
  • Engine and alternator pre-paint, Caterpillar yellow
 

Optional Equipment:

Certification
  • Certificate of Conformance
  • Australia, CIS, Gulf Certification
 
Auxiliary Supply Voltage
  • 120V
 
Alternator Requirements
  • Space heater
 
Fuel Storage
  • Dual wall 8 hour fuel tank
  • Single wall tank with containment
  • Low fuel level shutdown
  • High fuel level alarm
  • Low fuel level alarm
 
Genset Control
  • Volt free contacts for genset running
  • Emergency stop with key
  • Earth leakage
  • Volt free contacts for common alarm
  • Battery charger
  • Earth fault
  • Panel mounted audible alarm
  • Coolant heater
  • Standby Pack (Smart Jacket water heater, Battery charger)
  • Battery
  • Low coolant level shutdown
 
Circuit Breaker
  • 3 Pole Circuit breaker 160A
  • 3 Pole Circuit breaker 125A
  • 3 Pole Circuit breaker 200A
  • 4 Pole Circuit breaker 125A
  • 3 Pole Circuit breaker 400A
  • 4 Pole Circuit breaker 160A
  • 3 Pole Circuit breaker 250A
  • 4 Pole Circuit breaker 200A
  • 4 Pole Circuit breaker 250A
  • Circuit breaker padlock
  • 4 Pole Circuit breaker 400A
  • Neutral earth link
  • Overload via alarm switch on breaker
 
Testing & Packaging
  • PGS Test report @ 1.0 power factor
  • PGS Test report @ 0.8PF
 

    This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.