Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.

Generator Set Specifications
Frequency
60 Hz
Natural Gas Rating
230 eKW
Emissions/Fuel Strategy
U.S. EPA Certified for Non-Emergency Application
Speed
1800 rpm
Engine Specifications
Aspiration
Turbocharged - Aftercooled
Governor Type
Electronic
Bore
1463.1mm
Stroke
1728.3mm
Generator Set Dimensions
Length
2887kg
Width
57.6in
Height
68.04in
Weight
6364lb

Standard Equipment:

Cooling
  • Factory-installed radiator
  • Closed coolant recovery system
  • 50/50 Ethylene glycol antifreeze
  • Radiator and cooling fan complete with protective guards
  • Standard ambient temperatures up to 50°C (122°F)
 
Air Inlet
  • Single element air filter
 
Fuel
  • Low fuel pressure switch
  • Primary and secondary fuel shut-off
  • Fuel pressure test po
  • Dual lock off valves
  • Natural Gas or LP Vapor
  • NPT connection
 
Generator
  • Class H insulation material
  • Full load capacity alternator
  • Permanent magnet excitation
  • Class H insulation material
  • Full load capacity alternator
  • Integrated Voltage Regulator
  • Matched to the performance and output characteristics of Cat engines
  • Permanent magnet excitation
  • IP23 Protection
 
Exhaust
  • Exhaust outlet with 3” pipe
 
Controls
  • EMCP 4.2 Series generator set controller
 
Mounting
  • Vibration isolaton (puck type)
  • Rubber vibration isolators
 
Electric Power - Package Serial Number Prefix
  • Battery charging alternator
 
Electric Starting And/or Prelube
  • Battery cables
  • Engine electrical system
  • Solenoid activated starter motor
  • Solenoid activated starter motor
 
Governor
  • Electronic governor (non adjustable)
 
Control Panel
  • EMCP 4.2 Series generator set controller
 
Starting/charging
  • Batteries with rack and cables
  • 12 volt starting motor
 

Optional Equipment:

Starting/charging
  • Battery heater
  • Charging alternator
  • Jacket water heater
  • Battery charger – UL Listed 10 amp
 
General
  • Suitable for Use as Service Equipment (SUSE)
  • Automatic transfer switches (ATS)
  • CSA Certification
  • Enclosures: sound attenuated, weather protective
  • UL 2200 package
 
Generator
  • Anti-condensation heater
  • Shunt trip and auxiliary contact breaker
  • Thermal magnetic or electronic trip MCCBs
  • Excitation: [ ] Permanent Magnet Excited (PM)
  • Anti-condensation heater
  • Oversize and premium generators
 