Generator Set Specifications
-
- Frequency
- 60 Hz
- Natural Gas Rating
- 230 eKW
- Emissions/Fuel Strategy
- U.S. EPA Certified for Non-Emergency Application
- Speed
- 1800 rpm
-
Engine Specifications
-
- Aspiration
- Turbocharged - Aftercooled
- Governor Type
- Electronic
- Bore
- 1463.1mm
- Stroke
- 1728.3mm
-
Generator Set Dimensions
-
- Length
- 2887kg
- Width
- 57.6in
- Height
- 68.04in
- Weight
- 6364lb
Standard Equipment:
-
Cooling
-
- Factory-installed radiator
- Closed coolant recovery system
- 50/50 Ethylene glycol antifreeze
- Radiator and cooling fan complete with protective guards
- Standard ambient temperatures up to 50°C (122°F)
-
Air Inlet
-
- Single element air filter
-
Fuel
-
- Low fuel pressure switch
- Primary and secondary fuel shut-off
- Fuel pressure test po
- Dual lock off valves
- Natural Gas or LP Vapor
- NPT connection
-
Generator
-
- Class H insulation material
- Full load capacity alternator
- Permanent magnet excitation
- Class H insulation material
- Full load capacity alternator
- Integrated Voltage Regulator
- Matched to the performance and output characteristics of Cat engines
- Permanent magnet excitation
- IP23 Protection
-
Exhaust
-
- Exhaust outlet with 3” pipe
-
Controls
-
- EMCP 4.2 Series generator set controller
-
Mounting
-
- Vibration isolaton (puck type)
- Rubber vibration isolators
-
Electric Power - Package Serial Number Prefix
-
- Battery charging alternator
-
Electric Starting And/or Prelube
-
- Battery cables
- Engine electrical system
- Solenoid activated starter motor
- Solenoid activated starter motor
-
Governor
-
- Electronic governor (non adjustable)
-
Control Panel
-
- EMCP 4.2 Series generator set controller
-
Starting/charging
-
- Batteries with rack and cables
- 12 volt starting motor
Optional Equipment:
-
Starting/charging
-
- Battery heater
- Charging alternator
- Jacket water heater
- Battery charger – UL Listed 10 amp
-
General
-
- Suitable for Use as Service Equipment (SUSE)
- Automatic transfer switches (ATS)
- CSA Certification
- Enclosures: sound attenuated, weather protective
- UL 2200 package
-
Generator
-
- Anti-condensation heater
- Shunt trip and auxiliary contact breaker
- Thermal magnetic or electronic trip MCCBs
- Excitation: [ ] Permanent Magnet Excited (PM)
- Anti-condensation heater
- Oversize and premium generators